Here is Soap Wrapping Machine manufacturer talking about Causes And Troubleshooting Methods For Common Failures Of Wrapping Machine.
If you have any idea about it, welcome to contact us and discuss.
Causes and troubleshooting methods for common failures of packaging machines
Fault 1: The vacuum pump is not working or there is serious noise
the reason:
1. The power supply is out of phase or the fuse is open;
2. The vacuum pump is reversed;
3. Poor contact of IC main contact points.
4. ISJ normally closed contact is bad.
Method of exclusion:
1. Check the power supply line or change the fuse.
2. Power supply commutation.
3. Adjust or renew.
4. Adjust or renew.
Fault 2: no heat seal
the reason:
1. The nickel chrome skin is burned off.
2. The heat-sealed circuit line is loose and open.
Method of exclusion:
1. Replace it.
2. Tighten and reconnect. Imported pump
3. Adjust or renew.
4. Check if the 1SJ normally open 2SJ normally closed contact is good.
Fault 3: vacuum is not enough or no vacuum
the reason:
1. The bag is leaking.
2. There is no vacuum in the heat-sealed air chamber during vacuum.
3. The seal on the 1DT iron core seal or magnetic shield leaks.
Method of exclusion:
1. Change the packaging bag.
At the same time, Customized Toilet Block Wrapping Machine can be offered for you. Looking forward to receiving your inquiry.